# gln configuration file # # lines starting with # (like this one) are comments # lines starting with F0 or FR define global parameters # lines starting with F1 define the detector slot parameters # lines starting with F2 define the detector parameters # lines starting with F3 define the detector RTD/temp parameters # lines starting with F4 define the manifold parameters # # # Breakout box conditioning circuit calibration (i.e., c0-29) = 0.0703 26.0 # ADC Panel conditioning circuit calibration (i.e., c30-37) = 0.6499 10.72 # # # global parameters #F0 master_valve_num pres_adc pres_min pres_max #F0 c11.7 c38.1 -99 80 # pressures in psi F0 c0.2 c38.1 -99 80 # pressures in psi #FR min_range max_range (values outside this range means adc not connected?) FR 20 4900 # for temperature adcs #FV post-fill vent duration, in minutes (set to zero for no vent) FV 1 # disabled; usual enabled value = 10 # # # manifold/slot valve_num: # manifold 1: c11.1-c11.8 (i.e., 8 outlets per power strip) # manifold 2: c12.1-c12.8 # manifold 3: c13.1-c13.8 # manifold 4: c14.1-c14.8 # # slot parameters # valve_num is valve id for filling detector in this slot # olfo_adc is adc id for overflow sensor for filling detector in this slot # olfo_lim is adc value for liquid at overflow sensor #F1 slot_num man_num valve_num oflo_adc olflo_lim adc2K adc_offset # #dirk 8/14/2015 Dewar #F1 0 0 c12.4 c30.1 120 0.6499 10.72 F1 0 0 c0.4 c30.1 115 0.6499 10.72 # F1 1 1 c12.2 c0.2 960 0.0703 26.0 F1 2 1 c12.3 c1.2 990 0.0703 26.0 F1 3 1 c12.4 c2.2 950 0.0703 26.0 F1 4 2 c12.5 c3.2 1010 0.0703 26.0 F1 5 2 c12.6 c4.2 1000 0.0703 26.0 F1 6 4 c11.2 c5.2 990 0.0703 26.0 F1 7 3 c11.3 c6.2 1030 0.0703 26.0 F1 8 3 c11.4 c7.2 1090 0.0703 26.0 F1 9 3 c11.5 c8.2 1030 0.0703 26.0 F1 10 4 c11.6 c9.2 930 0.0703 26.0 F1 11 2 c12.7 c10.2 990 0.0703 26.0 F1 12 4 c11.7 c11.2 1000 0.0703 26.0 #fake, only for GRETINA shack T reading #F1 29 4 c11.2 c8.1 850 0.0703 26.0 # # # # detector parameters # slot_num is the slot where this detector is mounted, or -1 for not mounted # min_dur, max_dur are for duration in seconds # interval is fill interval in hours #F2 det_num slot_num min_dur max_dur interval F2 0 0 90 5400 8.0 F2 1 1 90 900 8.0 F2 2 2 90 900 8.0 F2 3 3 90 900 8.0 F2 4 4 90 900 8.0 F2 5 5 90 900 8.0 F2 6 6 90 900 8.0 F2 7 7 90 900 8.0 F2 8 8 90 900 8.0 F2 9 9 90 900 8.0 F2 10 10 90 900 8.0 F2 11 11 90 900 8.0 F2 12 12 90 900 8.0 # # 2014-02-12 CMC added "det29" back to monitor electronics shack temperature #F2 29 29 1 2 47.0 # # # detector RTD (temp) parameters # temp_adc is the adc id for the internal temperature of this detector # max_temp is the max detector temp for a happy system, with no alarm # max_HV is the max detector temp for HV allowed on crystal # adc2K, adc_offset are adc-to-temp conversion parameters #F3 det_num temp_adc max_temp max_HV adc2K adc_offset #F3 0 c0.1 500 500 0.6499 10.72 #AT ATLAS # #Dewar as detector 0, temp is shack temp since 6/10/19 #Dewar as detector 0, PT100 ovl and LN main in added in January 2020 #F3 0 c8.2 999 999 0.0703 26.0 F3 0 c30.1 2000 2000 0.6499 10.72 F3 0 c31.1 2000 2000 0.6499 10.72 # F3 1 c0.4 107 120 0.0703 26.0 F3 1 c0.6 107 120 0.0703 26.0 F3 1 c0.5 305 330 0.0703 26.0 F3 1 c0.3 321 330 0.0703 26.0 F3 2 c1.4 112 120 0.0703 26.0 #104 on its bbox F3 2 c1.6 111 120 0.0703 26.0 #103 on its bbox F3 2 c1.5 311 330 0.0703 26.0 F3 2 c1.3 315 330 0.0703 26.0 # F3 3 c2.4 108 120 0.0703 26.0 F3 3 c2.6 108 120 0.0703 26.0 F3 3 c2.5 309 330 0.0703 26.0 F3 3 c2.3 319 330 0.0703 26.0 # F3 4 c3.4 108 120 0.0703 26.0 F3 4 c3.6 108 120 0.0703 26.0 F3 4 c3.5 307 330 0.0703 26.0 F3 4 c3.3 318 330 0.0703 26.0 # F3 5 c4.6 114 120 0.0703 26.0 F3 5 c4.4 113 120 0.0703 26.0 F3 5 c4.5 309 330 0.0703 26.0 F3 5 c4.3 322 330 0.0703 26.0 # F3 6 c5.6 104 120 0.0703 26.0 F3 6 c5.4 106 120 0.0703 26.0 F3 6 c5.5 304 330 0.0703 26.0 F3 6 c5.3 322 330 0.0703 26.0 # F3 7 c6.6 111 120 0.0703 26.0 F3 7 c6.4 111 120 0.0703 26.0 F3 7 c6.5 306 330 0.0703 26.0 F3 7 c6.3 312 330 0.0703 26.0 # F3 8 c7.4 113 120 0.0703 26.0 F3 8 c7.6 113 120 0.0703 26.0 F3 8 c7.5 307 330 0.0703 26.0 F3 8 c7.3 318 330 0.0703 26.0 # F3 9 c8.6 105 120 0.0703 26.0 F3 9 c8.4 104 120 0.0703 26.0 F3 9 c8.5 306 330 0.0703 26.0 F3 9 c8.3 311 330 0.0703 26.0 # F3 10 c9.6 106 120 0.0703 26.0 F3 10 c9.4 106 120 0.0703 26.0 F3 10 c9.5 302 330 0.0703 26.0 F3 10 c9.3 309 330 0.0703 26.0 # F3 11 c10.6 108 120 0.0703 26.0 F3 11 c10.4 109 120 0.0703 26.0 # threshold modified to be 360 2020/4/29 by J.L. as bad preamp # temp reading gave PV error code, old value: 322 343 F3 11 c10.5 309 330 0.0703 26.0 F3 11 c10.3 313 330 0.0703 26.0 # F3 12 c11.6 109 120 0.0703 26.0 F3 12 c11.4 107 120 0.0703 26.0 F3 12 c11.5 307 330 0.0703 26.0 F3 12 c11.3 317 330 0.0703 26.0 # # temperature of electronics area #F3 29 c37.1 330 343 0.6499 10.72 #F3 29 c7.2 330 343 0.0703 26.0 #F3 29 c8.2 330 343 0.0703 26.0 #vme crate voltage 3.3V attenuated to 0.6V #F3 29 c40.1 330 343 0.4 26.0 # # # manifold parameters # valve_num is valve id for precooling this manifold # olfo_adc is adc id for overflow sensor for precooling this manifold # olfo_lim is adc value for liquid at overflow sensor # min_dur, max_dur are for duration in seconds # #dirk 8/14/2015: Wall manifold inlet PT100 at ADC#181 = c31.1 = BNC 30 #Danger: Missing check valve means that Dewar LN does flow back through #valve 2 and to wall manifold exhaust. DO NOT CHANGE olflo_lim 850 (!) #F4 man_num valve_num oflo_adc olflo_lim max_dur adc2K adc_offset F4 0 c0.3 c31.1 3000 1 0.6499 10.72 F4 1 c12.1 c33.1 120 600 0.6499 10.72 F4 2 c12.1 c33.1 120 600 0.6499 10.72 F4 3 c11.8 c32.1 120 800 0.6499 10.72 F4 4 c11.8 c32.1 120 800 0.6499 10.72